First Connect works, the second throws an error #121

Description

@amihaylo

Hi Pires, thanks for providing the obd api it's helped me tons!

I hope this is right way of going about asking for help, if not please redirect me and I will do so. I have had the issue for a while and am out of ideas which is why I turned to you in hopes of figuring out a solution to my problem.

So the first time I connect to OBD I have no issues and read the data just fine. If I however disconnect and try to reconnect, it fails and throws the following error:
W/System.err: com.github.pires.obd.exceptions.UnableToConnectException: Error running 01 46, response: ...UNABLETOCONNECT

After that failed attempt, if I try to reconnect again it works.

After every connection I make sure to close it with the Close Command as such:

CloseCommand closeCommand = new CloseCommand();
closeCommand.run(this.mmSocket.getInputStream(), this.mmSocket.getOutputStream());

Is there something I am not doing correctly? Possibly closing the streams? If so how would I go about doing that?