Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
With CONFIG_UEXT_OLED_DISPLAY=y and CONFIG_LV_TERMINAL_SOLAR=y, oled_update() does not select solar_terminal. If the HV terminal is a battery, compilation fails because in_terminal is undeclared. If the HV terminal is a nanogrid, it instead selects grid_terminal and displays grid power, voltage and daily energy in the solar input fields.
Include CONFIG_LV_TERMINAL_SOLAR in the existing solar-input condition. Both LV solar combinations are permitted by app/Kconfig, and setup.cpp already maps solar_terminal to lv_terminal for this configuration.
Validation: compiled and ran the actual extracted oled_update() function in a host C++ harness with simulated display and terminal interfaces. Before the fix, LV solar + HV battery failed to compile and LV solar + HV nanogrid displayed the wrong terminal. After the fix, both selected solar readings correctly. Existing HV solar, PWM solar and nanogrid-only selections also passed. Distinct solar (123 W) and grid (789 W) inputs verified the selected data. git diff --check passed.
This is an isolated function test. The full Zephyr firmware build and physical OLED hardware have not been tested.
Evidence audit — 17 November 2026
Public revision
15a2c0anow includestests/host/test_oled.py. Runpython3 tests/host/test_oled.pywith g++ installed. Five display configurations pass, including low-voltage solar with either high-voltage battery or grid. The old source either failed to compile in the former configuration or displayed grid power in the latter.The harness compiles the actual production function with hardware/display stand-ins. It is not a firmware or physical-device test. The combined native Zephyr suite also passes 103 tests, but this native configuration does not exercise this display/LED function; only the stated host harness does.